VP00 Pump Standard Specifications:
Pump Material: Anodized Aluminum (For silencer material, see the Accessories Section)
Cartridge Material: Nylon, Buna-N O-ring (Other material available, see pages 19-21)
Medium: Filtered (50 Micron) unlubricated, non-corrosive dry gases
Operating Temperature: 30° to ~250°F [-34° to ~121°C]
Operating Pressure: 80 PSI [5.5 bar] standard or 60 PSI [4.1 bar] – Consult Factory for other operating pressures
VP00 Operating and Installation Requirements:
Supply Line: Min. 5/32” [4mm], 1/4” O.D. [6mm] tube preferred for supply lines exceeding 3’ [1M]
Control Valve: 3 way/2 position (faster part release), minimum orifice – 0.062” diameter [1.57mm]
Vacuum Line: 1/4” [6mm] tube preferred, for short runs 5/32” [4mm] may be used
Vacuum Line Filtration: Typically vacuum filters are not required. If desired, Bimba recommends – VF125LPM. See the Accessories Section.
Mounting: Mounting holes accept 4-40 [M3] screws