Products

Mid Series Venturi Vacuum Pump - VP10

The VP10 Mid Series air-powered venturi vacuum pumps are highly efficient, capable of reaching 28”Hg [948mbar], dirt tolerant, and include a silencer for quiet operation. Lightweight and compact, they can be easily mounted close to the vacuum point for fast response. All Mid Series pumps incorporate Vaccon’s interchangeable venturi cartridge system that allows a choice of 11 different cartridge assemblies to optimize pump performance to meet specific application needs.

  • Safe operation – high flow, strong holding force
  • High productivity – powerful vacuum up to 28”Hg [948mbar]
  • Compact & lightweight – modular design speeds installation
  • Efficient – minimal air consumption Reliable – operates trouble-free:
  • Straight-through, no moving parts design, non-clogging
  • No maintenance, no downtime

 

To order the VP10 Series Venturi Pump, click here.

How to Order Content

The model number for the VP10 Series Venturi Vacuum Pumps consists of the base model acronym (VP10) plus six alphanumeric clusters. These clusters designate the flow and vacuum levels, operating pressure, port option, silencer and switch or sensor options. Refer to the chart below for an example of model number VP10-60H-60-ST4. This is a VP10 pump with a maximum vacuum flow of 60, maximum vacuum level of 28"Hg [948mbar], operating pressure of 60 PSI, ST4 silencer. Note, part numbers beginning with I- denote a model with G port metric threads.

 

VP10 How to Order

 

Additional Specs Content

VP10

 

VP10 Min Series Pump Standard Specifications

Pump Material: Anodized Aluminum (for silencer material see Silencer Page)

Cartridge Material:Nylon, Buna O-Ring
O-rings available in additional materials - Consult factory for availability

Medium: Filtered (50 micron) un-lubricated, non-corrosive dry gases

Operating Temperature:-30° to ~250°F [-34° to ~121°C]

Operating Pressure:80 PSI [5.5 bar] or 60 PSI [4.1 bar] – Consult Factory for other operating pressures

 
Performance Level Designations:

L”0-10”Hg, [0 to 677mbar] for low vacuum/high flow applications

M”0-20”Hg, [0 to 677mbar] for medium vacuum/high flow applications

H”0-28”Hg, [0 to 948mbar] for high vacuum/standard flow applications

 
VP10 Mid Series Operating and Installation Requirements

Cartridge Size: C60 (M, H) and C90 (L, M, H)C100 (L, M, H) and C150 (L, M, H)

Supply Line:1/4” O.D. [6mm] tube3/8” O.D. [10mm] tube

Vacuum Line:1/4” O.D. [6mm] tube3/8” O.D. [10mm] tube

Vacuum Line Filtration: Typically vacuum filters are not required, if desired Vaccon recommends model VF125LPM (see In-Line Filter Page)

Control Valve:3 way / 2 position (faster part release), minimum orifice – 0.125 I.D. [3 mm]

Mounting Screws: Mounting holes accept 10-32 [M5] screws