Products

Cylindrical Venturi Vacuum Pumps

Vaccon

J Series pumps are ideal for confined spaces, where they can be mounted in-line near the point of use for rapid response. The single-stage design allows ingested contaminants to flow through the pump without clogging ensuring continuous operation. J Series pumps provide a constant vacuum flow, rather than a fluctuating flow typically associated with diaphragm pumps. 

  • High performance - powerful vacuum up to 28"Hg [948mbar]
  • Durable – rugged aluminum body construction
  • Compact & lightweight – easily fits in confined spaces
  • Responsive – Mounts in-line, and installs close to vacuum point
  • Efficient – Minimal air consumption, provides instantaneous vacuum as needed
  • Safe operation – No electricity needed

To order the J Series Venturi Pump or to download CAD files, click here.

How to Order Content

The model number for the J Series Cylindrical Venturi Vacuum Pumps consists of the base model acronym (JF, JD JS) plus four alphanumeric clusters. Unlike the other Bimba | Vaccon venturi pups, the vacuum level is indicated by the J Series base model:

  • JF 10"Hg [339mbar]
  • JD 20"Hg [677mbar]
  • JS 28"Hg [948mbar]

The alphanumeric clusters designate the flow, operating pressure, silencer option and body material option. Refer to the 2nd chart below for an example of model number JS-200-60-ST6A-304. This is a JS Mid Series pump with a maximum vacuum flow of 200, maximum vacuum level of 28"Hg [948mbar] (JS), operating pressure of 60 PSI, optional ST6A silencer and optional 304 stainless steel body material (anodized aluminum is standard).

Notes: 

  • Part numbers beginning with I- denote a model with G port metric threads
  • Min J Series pumps add a "M" to the vacuum flow level designation, e.g. 100M
  • The Max J Series pumps have 3 alphanumeric clusters, the maximum vacuum flow is contained in the base model part number: JS-300 or JD-350, e.g. (there are 2 vacuum flow options for the Max J Series models).

 

J Min Series

J Min Series

J Mid Series

J Mid Series

J Max Series

J Max Series

 

Additional Specs Content

J Series

 

J-Series (Min - Mid - Max) Cylindrical Vacuum Pump Standard Specifications:
Pump Material:
Anodized Aluminum Standard 
Medium: Filtered (50 Micron) unlubricated, non-corrosive dry gases
Operating Temperature: -100° to ~400°F [-73° to ~204°C] (without silencer)
Operating Pressure: 80 PSI [5.5 bar] or 60 PSI [4.1 bar] – Consult Factory for other operating pressures


Performance Level Designations:

JF”  0-10”Hg, [0 to 339mbar] for low vacuum/high flow applications

JD”  0-20”Hg, [0 to 677mbar] for medium vacuum/high flow applications

JS”  0-28”Hg, [0 to 948mbar] for high vacuum/standard flow applications
 

Min J Series “M” Operating and Installation Requirements

Venturi Size:   60M and 90M                100M and 150M

Vacuum Line: 1/4” O.D. [6mm] tube     3/8” O.D. [10mm] tube

Supply Line:   1/4” O.D. [6mm] tube     3/8” O.D. [10mm] tube

Vacuum Line Filtration: Typically vacuum filters are not required, if desired Vaccon recommends model VF125LPM for 60M and 90M models and VF250LPM for 100 and 150M models (see In-Line Filter Page).

 
Mid J Series (100-250) Operating and Installation Requirements

Venturi Size:   J (100, 150, 200)             J250

Vacuum Line: 3/8” O.D. [10mm] tube     1/2” O.D. [12mm] tube

Supply Line:   3/8” O.D. [10mm] tube     1/2” O.D. [12mm] tube

Vacuum Line Filtration: Typically vacuum filters are not required, if desired Vaccon recommends model VF375F (see In-Line Filter Page)


Max J Series (300/350) Operating and Installation Requirements

Vacuum Line:1/2” O.D. [12mm] tube, 3/4” O.D. [19mm] for vacuum lines exceeding 3’ [1M] 

Supply Line:1/2” O.D. [12mm] tube 

Vacuum Line Filtration: Typically vacuum filters are not equipped, if desired Vaccon recommends model VF500F (see In-Line Filter Page)