Products

Max Series Venturi Vacuum Pump - VP80/VP80BV / VP90-MP

Vaccon

Bimba’s Multi-port venturi vacuum pumps combine a venturi with a manifold to distribute vacuum to multiple locations. The result is a compact and efficient vacuum generation and distribution system for End-of-Arm Tools and applications with multiple cups. The design minimizes vacuum loss, maximizes vacuum flow and speeds cycle times for safe, efficient lifting operations.

  • Compact – eliminates need for an external pump, install close to vacuum point
  • High Productivity – powerful vacuum up to 28”Hg [948mbar], fast response time
  • Compact & lightweight – reduces overall equipment weight
  • Efficient – minimal air consumption, high performance
  • Performance Optimization – precise control of flow and vacuum level
  • Reduces plumbing connections

To order the VP80 Series Venturi Pumps or to download CAD files, click here for VP80-MP Series or here for VP90-MP Series.

How to Order Content

[Using the VP80-250-MP - below middle graphic - as an example]. The model number for the VP80-250 Max Series Venturi Vacuum Pumps consists of the base model acronym* (VP80-250-MP, VP80BV-250 or VP80BVM8-250) plus four alphanumeric clusters. These clusters designate vacuum level, operating pressure, switch or sensor options and silencer. Refer to the chart below for an example of model number VP80-250-H-60-MP-VSMP-QD-6. This is a VP80-250 pump (maximum flow of 250) with a  maximum vacuum level of 28"Hg [948mbar], operating pressure of 60 PSI, and a VSMP vacuum switch with 6" pigtail quick disconnect. Note, part numbers beginning with I- denote a model with G port metric threads.The VP80-200-MP series has an extra alphanumeric cluster for the silencer selection; the VP80-250-MP and VP90-300/350-MP come standard with ST8A and ST8B silencers, respectively. The MP in all 3 models designate the pumps as multi-port.

Base model options:

VP80-250 indicates the base model
VP80BV-250 includes an optional integrated solenoid valve with flying leads
VP80BVM8-250 includes the optional integrated valve with M8 connector
*The VP80-250H and the VP90-MP Series cannot accommodate a solenoid valve

 

VP80-200-MP Series

How-to-order

VP80-250-MP Series

 

VP80-250

VP90-300/350-MP Series

VP90

Additional Specs Content

VP80

 

VP80-(200,250)-MP / VP80BV-(200,250)-MP Pump Standard Specifications

Pump and Cartridge Material: Anodized Aluminum (for silencer material see Silencer Page)

Medium: Filtered (50 micron) un-lubricated, non-corrosive dry gases

Operating Temperature:-100° to ~400°F [-73° to ~204°C]

Operating Pressure:80 PSI [5.5 bar] or 60 PSI [4.1 bar] – Consult Factory for other operating pressures

 
Performance Level Designations:

“L”0-10”Hg, [0 to 677mbar] for low vacuum/high flow applications

“M”0-20”Hg, [0 to 677mbar] for medium vacuum/high flow applications

“H”0-28”Hg, [0 to 948mbar] for high vacuum/standard flow applications

 
VP80BV-MP Optional 2-Way Valve Specifications

Valve Type:  Axial 2-Way Solenoid Valve, Normally closed

Valve Body Material: Brass, Aluminum, Buna-N

Valve Operating Pressure: Vacuum to 120 PSI [-1 to 8 bar]

Electrical:24 VDC [-15% to +10% Nominal]

Power Consumption:4 watts

Response Time:6 milliseconds

Cycle Rate:80 cycles/second

Average Life:100 million cycles

Electrical Connection:Fixed leads, 24 AWG, 18” [457.2mm], optional M8 3-pin connector

LED Indicator: Yes

Manual Override: Yes, non-locking, spring return

M8 3-pin Connection: Yes, optional


VP90-(300,350)-MP Multi-port Mid Series Operating and Installation Requirements

Supply Line:3.8” O.D. [10mm] tube 

Vacuum Line:3/8” O.D. [10mm] tube 

Vacuum Line Filtration: Typically vacuum filters are not required, if desired Vaccon recommends model VF375F (see In-Line Filter Page)

Control Valve:3 way / 2 position (faster part release), minimum orifice – 0.25 I.D. [6mm]

Mounting Screws: Mounting holes accept 10-32 or [M5] screws

VP90-(300,350)-MP Pump Standard Specifications

Pump and Cartridge Material: Anodized Aluminum (for silencer material see Silencer Page)

Medium: Filtered (50 micron) un-lubricated, non-corrosive dry gases

Operating Temperature:-100° to ~400°F [-73° to ~204°C]

Operating Pressure:80 PSI [5.5 bar] or 60 PSI [4.1 bar] – Consult Factory for other operating pressures

Performance Level Designations:

L”0-10”Hg, [0 to 677mbar] for low vacuum/high flow applications

M”0-20”Hg, [0 to 677mbar] for medium vacuum/high flow applications

H”0-28”Hg, [0 to 948mbar] for high vacuum/standard flow applications

 
VP90-(300,350)-MP Multi-port Mid Series Operating and Installation Requirements

Supply Line:1/2” O.D. [12mm] tube 

Vacuum Line:1/2” O.D. [12mm] tube – 3/4” [22mm] for lines exceeding 3’ [1M] 

Vacuum Line Filtration: Typically vacuum filters are not required, if desired Vaccon recommends model VF375F (see In-Line Filter Page)

Control Valve:3 way / 2 position (faster part release), minimum orifice – 0.25 I.D. [6mm]

Mounting Screws: Mounting holes accept 10-32 or [M5] screws