Max Series Venturi Vacuum Pump -VP90-MP

The VP90-300 & 350 Max Series air-powered Venturi vacuum pumps provide the highest vacuum flow rates of all Venturi pumps. The high flow producted by the VP90 Series pumps is ideal for the rapid evacuation of large volumes, or for overcoming leakage while maintaining high vacuum levels for the handling porous materials.

Highly efficient, capable of reaching 28"Hg (948 mbar), the VP90’s are dirt tolerant and include a silencer for quiet operation. Unlike the Mid series pumps that use interchangeable cartridge assemblies, the Max series pumps (VP80 & VP90’s) use a non-removable press-fit venturi assembly. 

  • Compact, lightweight and rugged construction
  • High performance – powerful vacuum up to 28"Hg [948mbar]
  • Able to mount close to vacuum point - fast response
  • Efficient – minimal air consumption
  • High flow overcomes leakage – maintains a strong holding force
  • No moving parts to clog or wear out

To order the VP80 Series Venturi Pump, click here or here for VP90-MP Series.

How to Order Content

[Using the VP80-250-MP - below middle graphic - as an example]. The model number for the VP80-250 Max Series Venturi Vacuum Pumps consists of the base model acronym* (VP80-250-MP, VP80BV-250 or VP80BVM8-250) plus four alphanumeric clusters. These clusters designate vacuum level, operating pressure, switch or sensor options and silencer. Refer to the chart below for an example of model number VP80-250-H-60-MP-VSMP-QD-6. This is a VP80-250 pump (maximum flow of 250) with a  maximum vacuum level of 28"Hg [948mbar], operating pressure of 60 PSI, and a VSMP vacuum switch with 6" pigtail quick disconnect. Note, part numbers beginning with I- denote a model with G port metric threads.The VP80-200-MP series has an extra alphanumeric cluster for the silencer selection; the VP80-250-MP and VP90-300/350-MP come standard with ST8A and ST8B silencers, respectively. The MP in all 3 models designate the pumps as multi-port.

 

VP90-300/350-MP Series

VP90

Additional Specs Content

VP80

 

VP80-(200,250)-MP / VP80BV-(200,250)-MP Pump Standard Specifications

Pump and Cartridge Material: Anodized Aluminum (for silencer material see Silencer Page)

Medium: Filtered (50 micron) un-lubricated, non-corrosive dry gases

Operating Temperature:-100° to ~400°F [-73° to ~204°C]

Operating Pressure:80 PSI [5.5 bar] or 60 PSI [4.1 bar] – Consult Factory for other operating pressures

 
Performance Level Designations:

“L”0-10”Hg, [0 to 677mbar] for low vacuum/high flow applications

“M”0-20”Hg, [0 to 677mbar] for medium vacuum/high flow applications

“H”0-28”Hg, [0 to 948mbar] for high vacuum/standard flow applications

 
VP80BV-MP Optional 2-Way Valve Specifications

Valve Type:  Axial 2-Way Solenoid Valve, Normally closed

Valve Body Material: Brass, Aluminum, Buna-N

Valve Operating Pressure: Vacuum to 120 PSI [-1 to 8 bar]

Electrical:24 VDC [-15% to +10% Nominal]

Power Consumption:4 watts

Response Time:6 milliseconds

Cycle Rate:80 cycles/second

Average Life:100 million cycles

Electrical Connection:Fixed leads, 24 AWG, 18” [457.2mm], optional M8 3-pin connector

LED Indicator: Yes

Manual Override: Yes, non-locking, spring return

M8 3-pin Connection: Yes, optional


VP90-(300,350)-MP Multi-port Mid Series Operating and Installation Requirements

Supply Line:3.8” O.D. [10mm] tube 

Vacuum Line:3/8” O.D. [10mm] tube 

Vacuum Line Filtration: Typically vacuum filters are not required, if desired Vaccon recommends model VF375F (see In-Line Filter Page)

Control Valve:3 way / 2 position (faster part release), minimum orifice – 0.25 I.D. [6mm]

Mounting Screws: Mounting holes accept 10-32 or [M5] screws

VP90-(300,350)-MP Pump Standard Specifications

Pump and Cartridge Material: Anodized Aluminum (for silencer material see Silencer Page)

Medium: Filtered (50 micron) un-lubricated, non-corrosive dry gases

Operating Temperature:-100° to ~400°F [-73° to ~204°C]

Operating Pressure:80 PSI [5.5 bar] or 60 PSI [4.1 bar] – Consult Factory for other operating pressures

Performance Level Designations:

L”0-10”Hg, [0 to 677mbar] for low vacuum/high flow applications

M”0-20”Hg, [0 to 677mbar] for medium vacuum/high flow applications

H”0-28”Hg, [0 to 948mbar] for high vacuum/standard flow applications

 
VP90-(300,350)-MP Multi-port Mid Series Operating and Installation Requirements

Supply Line:1/2” O.D. [12mm] tube 

Vacuum Line:1/2” O.D. [12mm] tube – 3/4” [22mm] for lines exceeding 3’ [1M] 

Vacuum Line Filtration: Typically vacuum filters are not required, if desired Vaccon recommends model VF375F (see In-Line Filter Page)

Control Valve:3 way / 2 position (faster part release), minimum orifice – 0.25 I.D. [6mm]

Mounting Screws: Mounting holes accept 10-32 or [M5] screws